Comments
- Two montors for bilevel tables. One motor for single surface tables.
- Electric motors are specially wrapped and insulated to avoid electromagnetic fields
which can interfere with the transmission of data.
- Motor is fused with an auto reset; approximately 14 minutes reset time.
- Toggle switch operation with high and low end cutoff.
- Motor comes with everthing needed for installation. (No electrician is required!)
- Fast and quiet (decibel level conforms to OSHA requirements for office environment).
- Installation: Motor simply insets into the Power Exchange Outlet (PXO) where it
engages the chain of your crank table. With the included allen wrench, insert one bolt
to lock into position, extend the toggle switch to the desired usage position and affix,
then run the power cord down the leg cable management channel to the wall outlet.
- If a problem does occur, reinstall your crank handle and you're operational until
the new kit is installed.
|